Skip to content
Advanced Fluro Private LimitedAUSTRALIA

Hose calculators

Size crimps, check offsets, estimate pressure loss and convert units. Every result is a guide — send us the numbers and our engineers will confirm.

01Calculator

Hose crimp diameter

Suggested crimp diameter from hose, shank and ferrule dimensions.

CRIMP DIAMETER (MM)
38.05 mm
CRIMP DIAMETER (IN)
1.498 in

Crimp diameter = shank OD + 2 × ferrule wall + (hose OD − hose ID) × (1 − compression %). A guide only — hydrostatic pressure testing of every assembly is strongly recommended, and PTFE assemblies should use the crimp spec for the fitting in use.

02Calculator

Pressure loss

Pressure drop along a straight hose or pipe run.

TOTAL PRESSURE DROP
31.52 kPa
TOTAL (PSI)
4.572 psi
DROP PER METRE
3.152 kPa/m
FLOW VELOCITY
2.351 m/s
REYNOLDS NUMBER
44,497
FLOW REGIME
Turbulent
FRICTION FACTOR (DARCY)
0.02171

Darcy–Weisbach, with the Colebrook–White friction factor for turbulent flow and 64/Re for laminar flow. Straight run only — add fittings and bends separately.

03Calculator

Offset and moving loops

Live hose length for offset motion and horizontal travelling loops.

Units

Offset motion

LIVE HOSE LENGTH, L
222.7 mm
PROJECTED LENGTH, LP
219.1 mm

L = √(6RX + X²), Lp = √(L² − X²), worked in inches. Keep X under 25% of R. If L and Lp differ a lot, take care at installation so the hose and braid aren’t stressed at full offset.

Horizontal moving loop

For a hose loop between a fixed and a travelling connection on the same horizontal plane.

LIVE HOSE LENGTH, L
1,271 mm
LOOP HEIGHT, H1
521.5 mm
LOOP HEIGHT AT REST, H2
286 mm

L = 4R + 1.57S, H1 = 1.43R + 0.785S, H2 = 1.43R.

04Calculator

Metallic corrosion resistance

How SS304, SS316, carbon steel and brass fittings stand up to common media.

35 of 35 media shown

Corrosion resistance of fitting metals by media, at ambient temperature
MEDIASS304SS316CARBON STEELBRASS
Acetic acid (glacial)2 · Limited use1 · Recommended3 · Not recommended3 · Not recommended
Acetone1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Air, compressed1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Ammonia, anhydrous1 · Recommended1 · Recommended1 · Recommended3 · Not recommended
Ammonium hydroxide1 · Recommended1 · Recommended2 · Limited use3 · Not recommended
Beer and wine1 · Recommended1 · Recommended3 · Not recommended2 · Limited use
Brine (sodium chloride)2 · Limited use2 · Limited use2 · Limited use2 · Limited use
Carbon dioxide, dry1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Chlorine, dry2 · Limited use2 · Limited use1 · Recommended2 · Limited use
Chlorine, wet3 · Not recommended3 · Not recommended3 · Not recommended3 · Not recommended
Citric acid1 · Recommended1 · Recommended3 · Not recommended2 · Limited use
Diesel1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Ethanol1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Ferric chloride3 · Not recommended3 · Not recommended3 · Not recommended3 · Not recommended
Formaldehyde1 · Recommended1 · Recommended2 · Limited use2 · Limited use
Hydraulic oil (mineral)1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Hydrochloric acid3 · Not recommended3 · Not recommended3 · Not recommended3 · Not recommended
Hydrofluoric acid3 · Not recommended3 · Not recommended3 · Not recommended3 · Not recommended
Hydrogen peroxide (30%)2 · Limited use1 · Recommended3 · Not recommended3 · Not recommended
Hydrogen sulphide, wet2 · Limited use2 · Limited use3 · Not recommended3 · Not recommended
Methanol1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Milk and dairy1 · Recommended1 · Recommended3 · Not recommended2 · Limited use
Nitric acid (10–65%)1 · Recommended1 · Recommended3 · Not recommended3 · Not recommended
Nitrogen1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Oxygen, gas1 · Recommended1 · Recommended2 · Limited use1 · Recommended
Petrol1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Phosphoric acid (10%)2 · Limited use1 · Recommended3 · Not recommended3 · Not recommended
Seawater2 · Limited use2 · Limited use3 · Not recommended2 · Limited use
Sodium hydroxide (20%)1 · Recommended1 · Recommended1 · Recommended2 · Limited use
Sodium hypochlorite3 · Not recommended2 · Limited use3 · Not recommended3 · Not recommended
Steam1 · Recommended1 · Recommended1 · Recommended2 · Limited use
Sulphuric acid (<10%)3 · Not recommended2 · Limited use3 · Not recommended3 · Not recommended
Sulphuric acid (98%)2 · Limited use2 · Limited use1 · Recommended3 · Not recommended
Toluene1 · Recommended1 · Recommended1 · Recommended1 · Recommended
Water, fresh1 · Recommended1 · Recommended2 · Limited use1 · Recommended

Ratings are for the fitting and ferrule metal at ambient temperature: 1 recommended, 2 partially resistant (not for continuous use), 3 not recommended for any use. Temperature, concentration and contamination change the picture — confirm with our engineers before you specify. The PTFE liner itself is rated in Chem Check.

05Calculator

Pressure conversion

bar, psi, kPa, MPa, atm, kgf/cm², head of water and more.

RESULT14.5038Pound per square inch (psi)1 Bar
06Calculator

Flow conversion

Volume and mass flow in metric, US and imperial units.

RESULT0.264172Gallon (US)/min1 Litre/min
07Calculator

Measurement conversion

Length, area, volume, mass and temperature.

MEASUREMENT
RESULT0.03937Inch (in)1 Millimetre (mm)

Have the numbers? Send them with your media and temperature and we’ll specify the hose.

Request a quote